Tray Cable

VNTC Shld 18 AWG – 16 AWG

Shielded tray TC-ER cable (VNTC) is used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. It can be installed in ducts, trays, conduit, direct buried and is moisture resistant. Rated for Class 1, Div 2 hazardous locations. All of our tray cables are manufactured to meet current NEC guidelines and are verified by UL.

Conductor: Twisted Stranded Bare Copper

Insulation: PVC/TFN

Shield: Overall Shield

Jacket: PVC

Flame Test: IEEE 383 70,000 BTU/hour Flame Test

Color Code:Click here

Color Code for K1 parts: Black, White, Red

VNTC Shld 14 AWG – 10 AWG

Application: Shielded TC-ER cable (VNTC) is used in 600 volt applications for process and control signals. Shielding protects the signal from eletrostatic noise and crosstalk. They can be installed in ducts, trays, conduit and direct buried. Rated for Class 1, Div 2 hazardous locations.

Conductor: Twisted Stranded bare copper

Insulation: PVC/THHN

Shield: Overall shield

Jacket: PVC

Flame Test: UL 1581 70,000 BTU/hour flame test

Color Code: Click here

VNTC Multi-Pair SP/OS 18 AWG – 16 AWG

Shielded TC-ER instrumentation cables are used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. They can be installed in ducts, trays, conduit and direct buried. Rated sunlight resistant for Class 1, Div 2 hazardous locations.

Conductor: Stranded bare copper

Insulation: PVC/TFFN

Shield: Individually shielded pairs Overall shield

Jacket: Sunlight Resistant PVC

Flame Test: UL 1581 70,000 BTU/hour flame test

Color Code:Method 9: Black and white pairs with printed numbers

VNTC Multi-Pair SP/OS – 14 AWG

Shielded TC-ER instrumentation cables are used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. They can be installed in ducts, trays, conduit and direct buried. Rated for Class 1, Div 2 hazardous locations.

Conductor: Stranded bare copper

Insulation: PVC/THHN-2

Shield: Individually shielded pairs Overall shield

Jacket: PVC

Flame Test: UL 1581 70,000 BTU/hour flame test

Color Code:Method 9: Black and white pairs with printed numbers

VNTC – 18 AWG

TC-ER cable (VNTC) is used in 600 volt applications for power and control signals. It can be installed in ducts, trays, conduit and direct buried. Rated for Class 1, Div 2 hazardous locations.

Conductor: Stranded bare copper

Insulation: PVC/TFFN

Jacket: Nylon/PVC

Flame Test: IEEE 383 70,000 BTU/hour flame test

Color Code: Click here

VNTC – 16 AWG

TC-ER cable (VNTC) is used in 600 volt applications for power and control signals. It can be installed in ducts, trays, conduit and direct buried. Rated for Class 1, Div 2 hazardous locations.

Conductor: Stranded bare copper

Insulation: PVC/TFFN

Jacket: Nylon/PVC

Flame Test: IEEE 383 70,000 BTU/hour flame test

Color Code: Click here

VNTC – 14 AWG

TC-ER cable (VNTC) is used in 600 volt applications for power and control signals. It can be installed in ducts, trays, conduit and direct buried and used as round submersible pump cable. Rated UV resistant for Class 1, Div 2 hazardous locations.  UL listed.

Conductor: Stranded Bare Copper

Insulation: PVC/THHN/THWN

Jacket: Nylon/PVC

Flame Test: IEEE 383 70,000 BTU/hour Flame Test 4

Color Code:Click here

VNTC – 10 AWG

TC-ER cable (VNTC) is used in 600-volt applications for power and control signals. It can be installed in ducts, wire ways, trays, conduit, direct burial, or exposed runs between cable trays and utilization equipment as well as Joist Pull (JP) applications in accordance with NEC 336.10 (&).. These products are also wet/dry UL rated and suitable for use as round submersible pump cable. Rated UV resistant for Class 1, Div 2 hazardous locations.  UL listed. 

Conductor: Stranded Bare Copper

Insulation: PVC/THHN/THWN

Jacket: Nylon/PVC

Flame Test: IEEE 383 70,000 BTU/hour Flame Test 4

Color Code:Click here

VNGTC 8 AWG – 750 MCM

Application: General purpose cable for use in primary power and feeder circuits in a broad range of commercial and industrial applications. Approved for installation indoors or outdoors aerially, in conduits, ducts, cable trays, or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations. UL approved for use in continuous operation at 90° in wet and dry locations, 105°C for short circuit conditions.

Conductors: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8

Insulation: Flame-retardant PVC per UL Standard 83 for Type THHN or THWN wire

Insulation Jacket: Clear nylon per UL Standard 83 for Type THHN or THWN wire

Grounding Conductor: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1277

Jacket: Sunlight-resistant PVC per UL Standard 1277

Flame Test: IEEE 383 (70,000 BTU/hr) Flame Test | ICEA (210,000 BTU/hr) flame Test

Color Code: ICEA Method 4  |  Click here

Additional Standards: UL Type TC per Article 336 of the NEC | UL Type TC-ER Rated for Exposed Run

XLPTC – 14 AWG

Application: XLP/PVC tray cables are used in power and control applications in the industrial and commercial markets where additional flame retardance is required. It can be direct buried or installed in cable trays.  This product has a XHHW-2 rating. TC-ER rated.

Conductor: Stranded bare copper

Insulation: XLP (Cross-Linked Polyethylene)

Jacket: PVC

Color Code: Click here

XLPTC – 12 AWG

Application: XLP/PVC tray cables are used in power and control applications in the industrial and commercial markets where additional flame retardance is required. It can be direct buried or installed in cable trays.  This product has a XHHW-2 rating. TC-ER rated.

Conductor: Stranded bare copper

Insulation: XLP (Cross-Linked Polyethylene)

Jacket: PVC

Color Code: Click here

XLPTC – 10 AWG

Application: XLP/PVC tray cables are used in power and control applications in the industrial and commercial markets where additional flame retardance is required. It can be direct buried or installed in cable trays.  This product has a XHHW-2 rating. TC-ER rated.

Conductor: Stranded bare copper

Insulation: XLP (Cross-Linked Polyethylene)

Jacket: PVC

Color Code: Click here

XLPGTC 8 AWG – 750 MCM

Application: XLP/PVC tray cables with a non-insulated copper ground are used in power and control applications in the industrial and commercial markets where additional flame retardance is required. XLP/PVC tray cable can be direct buried or installed in cable trays. This versatile item can also be installed both indoors and outdoors. This product has a XHHW-2 rating. TC-ER rated.

Insulation: XLP (Cross-Linked Polyethylene)

Jacket: PVC

Flame Test: IEEE 383 70,000 BTU/hour flame test

Color Code: Click here

FREPGTC 8 AWG – 750 MCM

Application: FR-EP (EPR or XLP/CPE) tray cables are used in power and control applications in the industrial and commercial markets where additional flame retardance is required. FR-EP tray cable can be direct buried or installed in cable trays. This versatile item can also be installed both indoors and outdoors. This product has a XHHW-2 rating and individual conductors are VW-1 rated.

Conductor: Stranded tinned copper

Insulation: EPR or XLP

Jacket: Chlorinated Polyethylene (CPE)

Flame Test: ICEA 210,000 BTU/hour flame test/IEEE 383 70,000 BTU/hour flame test Color

Code: Method 4 (M4) – A neutral or single-colored insulation compound is surface ink printed with conductor number to provide positive conductor identification through 21 conductors. The identification sequence is repeated for cables containing more than 21 conductors.

Color Code:Click here

FREP TC – 14 AWG

Application: FR-EP (EPR or XLP/CPE) tray cables are used in power and control applications in the industrial and commerical markets where additional flame retardance is required. FR-EP tray cable can be direct buried or installed in cable trays. This versatile item can also be installed both indoors and outdoors. This product has a XHHW-2 rating and individual conductors are VW-1 rated.

Conductor: Stranded tinned copper

Insulation: EPR or XLP

Jacket: Chlorinated Polyethylene (CPE) | Gas/Oil Resistant

Flame Test: ICEA 210,000 BTU/hour flame test/IEEE 383 70,000 BTU/hour flame test

Color Code: Click here

FREP TC – 12 AWG

Application: FR-EP (EPR or XLP/CPE) tray cables are used in power and control applications in the industrial and commerical markets where additional flame retardance is required. FR-EP tray cable can be direct buried or installed in cable trays. This versatile item can also be installed both indoors and outdoors. This product has a XHHW-2 rating and individual conductors are VW-1 rated.

Conductor: Stranded tinned copper

Insulation: EPR or XLP

Jacket: Chlorinated Polyethylene (CPE) | Gas/Oil Resistant

Flame Test: ICEA 210,000 BTU/hour flame test/IEEE 383 70,000 BTU/hour flame test

Color Code: Click here

FREP TC – 10 AWG

Application: FR-EP (EPR or XLP/CPE) tray cables are used in power and control applications in the industrial and commercial markets where additional flame retardance is required. FR-EP tray cable can be direct buried or installed in cable trays. This versatile item can also be installed both indoors and outdoors. This product has an XHHW-2 rating and individual conductors are VW-1 rated.

Conductor: Stranded tinned copper

Insulation: EPR or XLP

Jacket: Chlorinated Polyethylene (CPE) | Gas/Oil Resistant

Flame Test: ICEA 210,000 BTU/hour flame test/IEEE 383 70,000 BTU/hour flame test

Color Code: Click here