Distributor Wire & Cable
Spec Sheet


Type: PE-39 Rodent Resistant Outside Plant Phone Cable Distributor Wire and Cable
PE-39 | Direct Burial | Gopher/Rodent Resistant
Multi-Paired | 8 Mil Shield


DWC Part # Size AWG # of Pairs O.D. Inch Weight Lbs/M
2206PE39Goph 22 6 0.47 107
2212PE39Goph 22 12 0.59 167
2225PE39Goph 22 25 0.75 283
2250PE39Goph 22 50 0.99 490
1906PE39Goph 19 6 0.63 173
1912PE39Goph 19 12 0.79 285
1925PE39Goph 19 25 1.05 513
1950PE39Goph 19 50 1.37 940

PE-39 rodent resistance outside plant phone cable is used in direct burial applications where rodents or gopher resistance is needed.

  • Conductor: Solid bare copper
  • Insulation: Solid polyolefin
  • Filling Compound: The entire core assembly is filled with ETPR compound, filling the interstices between the pairs and under the core tape.
  • Shield: .005" corrugated copper clad alloy steel tape
  • Jacket: Black, linear low-density polyethylene
    Color Code:
    Cond. No. Color Code Cond. No. Color Code
    1 White w/ Blue Band 14 Black w/ Brown Band
    2 White w/ Orange Band 15 Black w/ Gray Band
    3 White w/ Green Band 16 Yellow w/ Blue Band
    4 White w/ Brown Band 17 Yellow w/ Orange Band
    5 White w/ Gray Band 18 Yellow w/ Green Band
    6 Red w/ Blue Band 19 Yellow w/ Brown Band
    7 Red w/ Orange Band 20 Yellow w/ Gray Band
    8 Red w/ Green Band 21 Purple w/ Blue Band
    9 Red w/ Brown Band 22 Purple w/ Orange Band
    10 Red w/ Gray Band 23 Purple w/ Green Band
    11 Black w/ Blue Band 24 Purple w/ Brown Band
    12 Black w/ Orange Band 25 Purple w/ Gray Band
    13 Black w/ Green Band - -

    Distributor Wire and Cable | Direct: 720.317.2277 | Fax: 720.317.2278 | www.distributorwire.com